No Free Freight

Tripp-Lite, 20kVA Smart Online 3-Phase UPS, Medium Frame Modular 4

MFG #: SV20KM1P4B
ATECH #: TRPSV20KM1P4B
UPC : 037332213426
Manufacturer : Tripp Lite
If you don't have an account, Become a Reseller!

Marketing Information

The SV20KM1P4B SmartOnline® SV Series 20kVA 3-Phase On-Line Double-Conversion UPS System delivers true scalability and offers the highest level of secure, uninterrupted power protection. Featuring a modular, scalable design with high-efficiency voltage and frequency independent (VFI) operation, this on-line UPS system is ideal for protecting a variety of critical IT systems.

The SV20KM1P4B includes pre-installed input, bypass and output breakers, as well as a static transfer switch (STS), one 20kVA SV20PM power module and four SVBM battery modules. Space is included for up to three additional user-installable SV20PM power modules.

The Java-free HTML5-based WEBCARDLX interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network.

With up to 92% efficiency in standard mode and up to 99% efficiency in optional economy mode, this 20kVA UPS system helps you reduce operating and cooling costs. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure. Front-panel display offers full UPS condition and status reporting.


Technical Specifications

  • UPC Code: 037332213426
  • UPS Type: On-Line
  • Input Phase: 3-Phase
  • Rated input current (Maximum Load): SV20KM1P4B 20kVA Configuration: 60A; Maximum 80kVA Configuration: 240A; 133A maximum inrush current
  • Nominal Input Voltage(s) Supported: 120/208V 3-PH Wye; 127/220V 3-PH Wye
  • Nominal Input Voltage Description: Set of two hardwire input connections enables 3-Phase Wye, 4 wire (3P, N, G) inputs from two separate power sources
  • UPS Input Connection Type: Hardwire
  • Input Circuit Breakers: MAIN and ALTERNATE AC inputs are each protected by 300A 3 pole magnetic breakers
  • Input Frequency: 40 to 70Hz (online mode); 50/60Hz Auto-selectable
  • Power Factor (Input): Greater than 0.99 (full load)
  • THDi: Less than 3% (full linear load)
  • Output Capacity (VA): 20000
  • Output Capacity (kVA): 20
  • Output Capacity (Watts): 18000
  • Output Capacity (kW): 18
  • Output Capacity Details: OVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1 minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less
  • Power Factor: 0.9
  • Crest Factor: 3:1
  • Nominal Voltage Details: Output THD full resistive load: <1.5%; Output THD non-linear load: <4%; Max DC offset: ±50mV; Max Phase angle deviation: 2°; Max Voltage unbalance deviation: 1%; Output short-circuit protection included
  • Frequency Compatibility: 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
  • Frequency Compatibility Details: Auto-selectable, user adjustable
  • Output Receptacle Details: Output wiring: 3P, N, E
  • Output Circuit Breakers: 300A 3 pole magnetic breaker
  • Output AC Waveform (AC Mode): Pure Sine wave
  • Output AC Waveform (Battery Mode): Pure Sine wave
  • Nominal Output Voltage(s) Supported: 120/208V 3-PH Wye; 127/220V 3-PH Wye
  • Output Receptacles: Hardwire
  • Output Voltage Regulation: ONLINE, FREQUENCY CONVERSION, BATTERY MODE: 208/120, 220/127 ±1% typical (balanced load); ±2% typical (unbalanced load); ECONOMY MODE: 208/120, 220/127 ±15V; BYPASS MODE: +15% (default, adjustable to +10%, +15% or +20%), -20% (default, adjustable to -10%, -20%, -30%)
  • Output Frequency Regulation: ONLINE MODE: Output frequency is ±0.05Hz of input frequency when input is within ±4Hz* of the configured 50/60Hz output setting; Output frequency is ±0.05Hz the configured 50/60Hz output setting when input is outside ±4Hz* of the configured 50/60Hz output setting; BATTERY MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; FREQUENCY CONVERTER MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; ECONOMY MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (UPS switches to Online mode if frequency goes outside of this range); BYPASS MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (switches to STANDBY mode if frequency goes outside of this range). *The TRACKING RANGE is factory set to ±4Hz and is user adjustable to ±1Hz, ±2Hz or ±4Hz; The selected TRACKING RANGE setting controls frequency output tolerances as described above in Online, Economy and Bypass modes
  • Output Amp Capacity: Output Amp Capacity 55.5A (208/120V); 52.5A (220/127V)
  • Modular Upgrade Options: Includes 1 SV20PM 20kVA power module; Up to 3 additional SV20PM 20kVA power modules can be added for increased capacity or enhanced N+1 redundancy; Add 1 SV20PM for 40kVA capacity (or 20kVA with N+1); Add 2 SV20PM for 60kVA capacity (or 40kVA with N+1); Add 3 SV20PM for 80kVA capacity (or 60kVA with N+1)
  • Runtime Full Load (min.): 24.5 min. (20kVA)
  • Runtime Half Load (min.): 52 min. (10kVA)
  • Expandable Runtime: Yes
  • Expandable Runtime Description: For extended runtimes beyond those provided by internal battery modules, please review the suffix "0B" SV models without internal battery modules, which offer different external battery pack options.
  • DC System Voltage (VDC): ±120VDC
  • Battery Recharge Rate (Included Batteries): User selectable charging current of 1A to 8A (2A factory setting); Recharge rate for internal batteries is 4.6 hours to 90% capacity (7A charging current)
  • Battery Replacement Description: Hot-swappable, replaceable batteries
  • Voltage Regulation Description: Online, double-conversion power conditioning
  • Overvoltage Correction: Maintains continuous output in online mode, without using battery power, during overvoltages to 253V (Ph-Ph), reducing output to within 1% of selected 208/120V, 220/127V nominal output voltage
  • Undervoltage Correction: Maintains continuous output in online mode, without using battery power, during brownout/undervoltage conditions to 156V (Ph-Ph) at full load and to 121V (Ph-Ph) at 70% output load or less, increasing output to within 1% of selected 208/120V or 220/127V nominal output voltage
  • Front Panel LCD Display: 145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions
  • Switches: Front panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch
  • Alarm Cancel Operation: Audible alarms can be muted using on-screen prompts
  • Audible Alarm: Unique audible alarms for POWER ON / POWER OFF (alarm sounds for 2 seconds), BATTERY MODE (alarm sounds every 2 seconds), LOW BATTERY (alarm sounds every 0.5 seconds), UPS ALARM (alarm sounds every 1 second), UPS FAULT (continuous alarm)
  • LED Indicators: Front panel LED indicators represent INPUT (green), BYPASS (amber), INVERTER (green), BATTERY (red) and ALARM (red)
  • EMI / RFI AC Noise Suppression: Yes
  • AC Suppression Joule Rating: 2496
  • AC Suppression Joule Rating: 2496 joules (Ph-Ph), 2496 joules (Ph-N), 1872 joules (N-E)
  • AC Suppression Response Time: Instantaneous
  • Primary Form Factor: Tower
  • Cooling Method: Fans
  • Installation Form Factors Supported with Included Accessories: Tower
  • Primary UPS Depth (mm): 1,100
  • Primary UPS Height (mm): 2,010
  • Primary UPS Width (mm): 600
  • Shipping Dimensions (hwd / in.): 54.50 x 28.50 x 42.50
  • Shipping Weight (lbs.): 1058.00
  • UPS Housing Material: Steel
  • UPS Power Module Dimensions (hwd, in.): 79.13 x 23.62 x 43.3
  • UPS Power Module Weight (kg): 725.29
  • UPS Power Module Weight (lbs.): 1599
  • Unit Dimensions (hwd / in.): 45.800 x 20.500 x 33.700
  • Operating Temperature Range: 0° to +40°C (+32° to +104°F); De-rates to 90% capacity at 35°C / 95°F and 80% capacity at 40°C / 104°F
  • Storage Temperature Range: -15° to +60°C (+5° to +140°F)
  • Relative Humidity: 0 to 95%, non-condensing
  • AC Mode BTU / Hr. (Full Load): 6074
  • AC Economy Mode BTU / Hr. (Full Load): 853
  • AC Economy Mode Efficiency Rating (100% Load): 99%
  • Audible Noise: Less than 73 DBA front-side, 1m
  • Operating Elevation (m): Up to 1000m (At elevations over 1000m, output de-rates by 1% per 100m)
  • Network Management Cards: WEBCARDLX ; MODBUSCARDSV ; RELAYCARDSV
  • Network Monitoring Port Description: Includes pre-installed Tripp Lite WEBCARDLX network interface
  • PowerAlert Software: For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
  • Communications Cable: DB9 cabling included
  • SNMP Compatibility: Includes pre-installed WEBCARDLX network interface card
  • Communications Interface: DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface
  • Transfer Time: No transfer time (0 ms.) in online, double-conversion mode; Less than 20 ms. transfer time in economy mode
  • Low Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation without using battery power during brownout/undervoltage conditions to to 156V (Ph-Ph) Full load or 121V (Ph-Ph) 70% load or less; Below the low transfer voltage point, output is maintained utilizing reserve battery power
  • High Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation without using battery power during overvoltages to 253V (Ph-Ph), reducing output within 1% of nominal; Above this point, output is maintained utilizing reserve battery power
  • Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
  • High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries; Auto Probe Monitoring (included); Zero transfer time; On-Line/Double-Conversion
  • Green Energy-Saving Features: Greater than 95% efficiency - GREEN UPS; High efficiency economy mode operation; Schedulable daily hours of economy mode operation
  • UPS Applications: Mission Critical Applications
  • Product Certifications: CSA (Canada); NOM (Mexico); UL 1778
  • Product Compliance: RoHS; FCC Part 15 Class A (USA)
  • Product Warranty Period (U.S. & Canada): 1-year limited warranty
  • 3-Phase Warranty Statement: Tripp Lite 3-Phase UPS Factory Warranty
Net Weight: 1058.00 lbs
UOM: EACH
Product Type: UPS Battery Backup
Warranty: 1 Year Limited Warranty
Pack Dimensions: 54.50"h x 42.50"w x 28.50"l

Recent Invoices (showing the last 15 invoices)

Invoice No PO Number Ship to Name Quantity Unit Price Date